Two “scores” will be assigned to each crossing:

  1. Culverts with performance problems will be flagged.
  2. A condition score (0.0-1.0) is calculated for each crossing, as follows:
    1. For each culvert, assign a score for each of the three variables below (V1, V2, V3) using data from the Condition Assessment Form.
    2. The minimum score resulting from V1, V2, or V3 is the overall condition score for each culvert. The score will range from 0 (most critical condition) to 1 (good condition).

      PLUS

      If any Section is marked “Unknown” then add “not fully assessed” to the score unless the score is 0.0. For example: “0.7-not fully assessed” or “0.3-not fully assessed” but not “0-not fully assessed” 
       
    3. For multiple culvert crossings, the overall condition score for the crossing is the lowest condition score among the culverts that make up the crossing. 

V1 Structural Deficiency – Highly Critical

Variables marked “Critical”

Score

Any one of the following

0.0

Cross-Section Deformation

Inlet or outlet

Structural Integrity of Barrel

Inlet or outlet

Footings

Inlet or outlet

Level of Blockage

Inlet or outlet

V2 Structural Deficiency – Critical

Variables marked “Critical”

Score

Any three or more of the following

Any two of the following

Any one of the following

0.0

0.1

0.2

Buoyancy or Crushing

Inlet or outlet or both counts as 1

Invert Deterioration

Inlet or outlet or both counts as 1

Joints and Seams

Inlet or outlet or both counts as 1

Longitudinal Alignment

Inlet or outlet or both counts as 1

Headwall/Wingwalls

Inlet or outlet or both counts as 1

Flared End Section

Inlet or outlet or both counts as 1

Apron/Scour Protection

Outlet

Armoring

Inlet or outlet or both counts as 1

Embankment Piping

Inlet or outlet or both counts as 1

Variables marked “Poor”

Score

Any three or more of the following

Any two of the following

Any one of the following

0.0

0.1

0.2

Cross-Section Deformation

Inlet or outlet or both counts as 1

Structural Integrity of Barrel

Inlet or outlet or both counts as 1

Footings

Inlet or outlet or both counts as 1

Level of Blockage

Inlet or outlet or both counts as 1

V3 Structural Deficiency – Poor

Variables marked “Poor”

Score

For each of the following identified as “Poor”

0.1 pt. deduction from 1.0 down to a minimum score of 0.3

Buoyancy or Crushing

Inlet or outlet or both counts as 1

Invert Deterioration

Inlet or outlet or both counts as 1

Joints and Seams

Inlet or outlet or both counts as 1

Longitudinal Alignment

Inlet or outlet or both counts as 1

Headwall/Wingwalls

Inlet or outlet or both counts as 1

Flared End Section

Inlet or outlet or both counts as 1

Apron/Scour Protection

Outlet

Armoring

Inlet or outlet or both counts as 1

Embankment Piping

Inlet or outlet or both counts as 1